residual current monitors e.Guard RCM B 025

09344367, Residual current monitor, Ethernet (LAN), Type B, 25 mm
  • 25 mm Ø (inner), Type B, 0 Hz ... 100 kHz
  • Residual operating current I∆n 3 A
  • Output of nominal response residual currents via Ethernet (Modbus TCP)
  • monitored circuit max. 400 V (AC), 63 A
  • alarm message via relay
New

residual current monitors e.Guard RCM B 025

09344367, Residual current monitor, Ethernet (LAN), Type B, 25 mm
  • 25 mm Ø (inner), Type B, 0 Hz ... 100 kHz
  • Residual operating current I∆n 3 A
  • Output of nominal response residual currents via Ethernet (Modbus TCP)
  • monitored circuit max. 400 V (AC), 63 A
  • alarm message via relay

Details

Residual current monitor, Ethernet (LAN), Type B, 25 mm

Residual current monitors (RCM) reliably detect and report fault and differential currents without switching off the system. They are used wherever the system cannot be switched off, or this is not desired. Smart, all-current-sensitive residual current monitors (type B) reliably detect fault as well as residual currents and report them without switching off the system. The Ethernet interface transmits the measured residual current values via Modbus TCP protocol. The smart residual current monitors are an integral part of the e.Guard system, regardless of the selected e.Guard LEVEL.

suitable for detecting Type B residual currents, monitored frequency range 0 Hz – 100 kHz, monitored circuit max. 400 V (AC), 63 A, robust plastic housing, easy installation, Configuration of various settings and sending of residual current values over Ethernet, 2 configurable alarm relays with potential-free changeover contacts, Operating voltage from PoE (Power over Ethernet) or direct 24 V DC connection

They are attached to a mounting rail.

The monitoring device is suitable for use in power supplied to purpose-built buildings and industrial facilities with TN-S, TN-C-S networks, IT networks and direct current networks, such as in server rooms for data centres, laboratories, in the automotive industry and in conjunction with photovoltaic and UPS systems with frequency converters without transformers, air conditioning systems, frequency converters, switching power supplies, high-frequency converters, printing machines and packaging machines. , Suitable for monitoring DC circuits and systems in which electronic equipment may generate smooth DC residual currents or residual currents with frequencies not equal to 50 Hz.

The device is supplied pre-configured and can be commissioned without further settings and operated standalone without e.Guard. Further information is available online: www.eguard.de.

Residual current monitor, Ethernet (LAN), Type B, 25 mm

Residual current monitors (RCM) reliably detect and report fault and differential currents without switching off the system. They are used wherever the system cannot be switched off, or this is not desired. Smart, all-current-sensitive residual current monitors (type B) reliably detect fault as well as residual currents and report them without switching off the system. The Ethernet interface transmits the measured residual current values via Modbus TCP protocol. The smart residual current monitors are an integral part of the e.Guard system, regardless of the selected e.Guard LEVEL.

suitable for detecting Type B residual currents, monitored frequency range 0 Hz – 100 kHz, monitored circuit max. 400 V (AC), 63 A, robust plastic housing, easy installation, Configuration of various settings and sending of residual current values over Ethernet, 2 configurable alarm relays with potential-free changeover contacts, Operating voltage from PoE (Power over Ethernet) or direct 24 V DC connection

They are attached to a mounting rail.

The monitoring device is suitable for use in power supplied to purpose-built buildings and industrial facilities with TN-S, TN-C-S networks, IT networks and direct current networks, such as in server rooms for data centres, laboratories, in the automotive industry and in conjunction with photovoltaic and UPS systems with frequency converters without transformers, air conditioning systems, frequency converters, switching power supplies, high-frequency converters, printing machines and packaging machines. , Suitable for monitoring DC circuits and systems in which electronic equipment may generate smooth DC residual currents or residual currents with frequencies not equal to 50 Hz.

The device is supplied pre-configured and can be commissioned without further settings and operated standalone without e.Guard. Further information is available online: www.eguard.de.