wiring components EV-S G 3.1+N.18.120
- for the supply-side connection of RCCB, MCB and RCBO on the underside of the device
- Design fork
- Length 320 mm
- large cross-section (10 mm²), high rated current of 63 A
wiring components EV-S G 3.1+N.18.120
- for the supply-side connection of RCCB, MCB and RCBO on the underside of the device
- Design fork
- Length 320 mm
- large cross-section (10 mm²), high rated current of 63 A
Details
Busbar, fork, 4-pole, 18 MW (module width), 63 A ((L1+N, L2+N, L3+N) x 3)
These components for the wiring of circuit breakers in industrial, commercial and privately used electrical distribution units significantly reduce the installation work. The cut to length busbars are suitable for the supply-side connection of residual current circuit-breakers, miniature circuit-breakers (MCBs) and residual current operated circuit-breakers with integral overcurrent protection (RCBOs) on the bottom of the devices. The bars with furcated cable lug are available in a wide range of variants in one to four-pole design (some also with space for auxiliary switches) and provide time-saving and user-friendly processing options. Unused connections can be covered by the EV-S BS protective cover.
can be used in connection with residual current circuit-breakers, miniature circuit-breakers and residual current operated circuit-breakers with integral overcurrent protection , wide range of variants , saves a lot of time during wiring
The rails are inserted in the upper or lower terminals of the devices to be connected.
Busbars from this series are used in connection with RCCBs, MCBs and RCBOs in power supplies to residential and purpose-built buildings as well as to industrial facilities.
The EV-S G ANL (N left) or EV-S G ANR (N right) connection bars must be used when supplying power to miniature circuit-breakers from above in combination with Doepke residual current circuit-breakers.
Busbar, fork, 4-pole, 18 MW (module width), 63 A ((L1+N, L2+N, L3+N) x 3)
These components for the wiring of circuit breakers in industrial, commercial and privately used electrical distribution units significantly reduce the installation work. The cut to length busbars are suitable for the supply-side connection of residual current circuit-breakers, miniature circuit-breakers (MCBs) and residual current operated circuit-breakers with integral overcurrent protection (RCBOs) on the bottom of the devices. The bars with furcated cable lug are available in a wide range of variants in one to four-pole design (some also with space for auxiliary switches) and provide time-saving and user-friendly processing options. Unused connections can be covered by the EV-S BS protective cover.
can be used in connection with residual current circuit-breakers, miniature circuit-breakers and residual current operated circuit-breakers with integral overcurrent protection , wide range of variants , saves a lot of time during wiring
The rails are inserted in the upper or lower terminals of the devices to be connected.
Busbars from this series are used in connection with RCCBs, MCBs and RCBOs in power supplies to residential and purpose-built buildings as well as to industrial facilities.
The EV-S G ANL (N left) or EV-S G ANR (N right) connection bars must be used when supplying power to miniature circuit-breakers from above in combination with Doepke residual current circuit-breakers.