residual current circuit-breaker DRCCB 5 STR 063-4/0,03-A

09441504, Residual current circuit-breakers, four-pole, 63 A, 0,03 A, Type A, Selftest Restart, N right
  • sensitive to pulsating and alternating currents, mains-voltage-independent
  • with self-test and restart
  • large connection terminals up to 35 mm²

residual current circuit-breaker DRCCB 5 STR 063-4/0,03-A

09441504, Residual current circuit-breakers, four-pole, 63 A, 0,03 A, Type A, Selftest Restart, N right
  • sensitive to pulsating and alternating currents, mains-voltage-independent
  • with self-test and restart
  • large connection terminals up to 35 mm²

Details

Residual current circuit-breakers, four-pole, 63 A, 0,03 A, Type A, Selftest Restart, N right

Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. Series DRCCB 5 devices are compact two or four-pole residual current circuit-breakers with self-test function. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches in the Selftest Restart design automatically perform a regular function test of the residual current circuit-breaker. This function test occurs without interruption. After tripping, the residual current circuit-breaker is automatically reactivated. The required power supply is integrated. The automatic function can be switched off.

monthly self-test, automatic insulation testing before the restart attempt, no restart attempted if a fault is detected, signalling the operating status by LEDs, configurable auxiliary contact

quick fastening to mounting rail, any installation position, supply from top

The devices can be used anywhere where electrical systems must not be shut down or are difficult to access. These may be, for example, IT and telecommunications systems, agricultural facilities, small wind power stations or sewage treatment plants, Using an optional Modbus interface module, the switching status of the RCCB can be transmitted for remote monitoring.

Residual current circuit-breakers, four-pole, 63 A, 0,03 A, Type A, Selftest Restart, N right

Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. Series DRCCB 5 devices are compact two or four-pole residual current circuit-breakers with self-test function. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches in the Selftest Restart design automatically perform a regular function test of the residual current circuit-breaker. This function test occurs without interruption. After tripping, the residual current circuit-breaker is automatically reactivated. The required power supply is integrated. The automatic function can be switched off.

monthly self-test, automatic insulation testing before the restart attempt, no restart attempted if a fault is detected, signalling the operating status by LEDs, configurable auxiliary contact

quick fastening to mounting rail, any installation position, supply from top

The devices can be used anywhere where electrical systems must not be shut down or are difficult to access. These may be, for example, IT and telecommunications systems, agricultural facilities, small wind power stations or sewage treatment plants, Using an optional Modbus interface module, the switching status of the RCCB can be transmitted for remote monitoring.