residual current circuit-breaker DRCCB 5 STR 063-4/0,03-A
- sensitive to pulsating and alternating currents, mains-voltage-independent
- with self-test and restart
- large connection terminals up to 35 mm²
residual current circuit-breaker DRCCB 5 STR 063-4/0,03-A
- sensitive to pulsating and alternating currents, mains-voltage-independent
- with self-test and restart
- large connection terminals up to 35 mm²
Details
Residual current circuit-breakers, four-pole, 63 A, 0,03 A, Type A, Selftest Restart, N right
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. Series DRCCB 5 devices are compact two or four-pole residual current circuit-breakers with self-test function. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches in the Selftest Restart design automatically perform a regular function test of the residual current circuit-breaker. This function test occurs without interruption. After tripping, the residual current circuit-breaker is automatically reactivated. The required power supply is integrated. The automatic function can be switched off.
monthly self-test, automatic insulation testing before the restart attempt, no restart attempted if a fault is detected, signalling the operating status by LEDs, configurable auxiliary contact
quick fastening to mounting rail, any installation position, supply from top
The devices can be used anywhere where electrical systems must not be shut down or are difficult to access. These may be, for example, IT and telecommunications systems, agricultural facilities, small wind power stations or sewage treatment plants, Using an optional Modbus interface module, the switching status of the RCCB can be transmitted for remote monitoring.
- Operating instructions
- Data sheet
- Prospectus Circuit-breaker overview
- Prospectus Remote actuators DFA 2/3, Selftest/Selftest Restart
- Technical information Derating curve for DRCCB
- Text for invitation to tender RTF
- Text for invitation to tender GAEB XML
- Text for invitation to tender GAEB 2000
- Text for invitation to tender GAEB 90
- Dimensional drawing Group view
- STEP file
- Wiring diagram
Residual current circuit-breakers, four-pole, 63 A, 0,03 A, Type A, Selftest Restart, N right
Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. Series DRCCB 5 devices are compact two or four-pole residual current circuit-breakers with self-test function. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches in the Selftest Restart design automatically perform a regular function test of the residual current circuit-breaker. This function test occurs without interruption. After tripping, the residual current circuit-breaker is automatically reactivated. The required power supply is integrated. The automatic function can be switched off.
monthly self-test, automatic insulation testing before the restart attempt, no restart attempted if a fault is detected, signalling the operating status by LEDs, configurable auxiliary contact
quick fastening to mounting rail, any installation position, supply from top
The devices can be used anywhere where electrical systems must not be shut down or are difficult to access. These may be, for example, IT and telecommunications systems, agricultural facilities, small wind power stations or sewage treatment plants, Using an optional Modbus interface module, the switching status of the RCCB can be transmitted for remote monitoring.
- Operating instructions
- Data sheet
- Prospectus Circuit-breaker overview
- Prospectus Remote actuators DFA 2/3, Selftest/Selftest Restart
- Technical information Derating curve for DRCCB
- Text for invitation to tender RTF
- Text for invitation to tender GAEB XML
- Text for invitation to tender GAEB 2000
- Text for invitation to tender GAEB 90
- Dimensional drawing Group view
- STEP file
- Wiring diagram