residual current circuit-breaker DFS 6 040-4/0,03-A NU
- sensitive to pulsating and alternating currents, mains-voltage-independent
- minimal power dissipation at each pole
- large connection terminals up to 50 mm²


residual current circuit-breaker DFS 6 040-4/0,03-A NU
- sensitive to pulsating and alternating currents, mains-voltage-independent
- minimal power dissipation at each pole
- large connection terminals up to 50 mm²
Details
Residual current circuit-breakers, four-pole, 40 A, 0,03 A, Type A, mains monitoring, N left
Type A residual current circuit-breakers detect pulsating direct current and alternating current. Thanks to the mains monitoring function, our NU RCCBs also trip in the event of input-side mains disturbances, such as a neutral conductor interruption. This reliably protects electrical equipment against overvoltage damage.
tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents and pulsating DC residual currents (type A) , compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor cross-section and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "off" and "tripped", Neutral conductor position left
quick fastening to mounting rail, any installation position, supply from any direction
Power supplies to residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the residual current circuit-breakers of this series can be set to switch off in the event of a second fault, Excluded is the application in TN-C systems and for the protection of installations in which electronic equipment could generate smooth DC currents or residual currents with frequencies other than 50 Hz. Comprehensive protection is not provided in this case. For these applications we recommend our AC/DC sensitive residual current circuit-breakers (Type B or B+).
- Data sheet DFS6 040-4/0,03-A NU
- Operating instructions
- Technical information Derating graph for DFS 2/4
- Technical information dissipation power DFS 2/4
- Prospectus Focus on the neutral conductor. Switching devices with mains monitoring
- Prospectus Installation recommendation switching devices with mains monitoring
- Text for invitation to tender RTF
- Text for invitation to tender GAEB XML
- Text for invitation to tender GAEB 2000
- Text for invitation to tender GAEB 90
- Dimensional drawing Group view
- Wiring diagram
- Product video Mains monitoring with the new DFS NU and DHS NU/NUS
Residual current circuit-breakers, four-pole, 40 A, 0,03 A, Type A, mains monitoring, N left
Type A residual current circuit-breakers detect pulsating direct current and alternating current. Thanks to the mains monitoring function, our NU RCCBs also trip in the event of input-side mains disturbances, such as a neutral conductor interruption. This reliably protects electrical equipment against overvoltage damage.
tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents and pulsating DC residual currents (type A) , compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor cross-section and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "off" and "tripped", Neutral conductor position left
quick fastening to mounting rail, any installation position, supply from any direction
Power supplies to residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the residual current circuit-breakers of this series can be set to switch off in the event of a second fault, Excluded is the application in TN-C systems and for the protection of installations in which electronic equipment could generate smooth DC currents or residual currents with frequencies other than 50 Hz. Comprehensive protection is not provided in this case. For these applications we recommend our AC/DC sensitive residual current circuit-breakers (Type B or B+).
- Data sheet DFS6 040-4/0,03-A NU
- Operating instructions
- Technical information Derating graph for DFS 2/4
- Technical information dissipation power DFS 2/4
- Prospectus Focus on the neutral conductor. Switching devices with mains monitoring
- Prospectus Installation recommendation switching devices with mains monitoring
- Text for invitation to tender RTF
- Text for invitation to tender GAEB XML
- Text for invitation to tender GAEB 2000
- Text for invitation to tender GAEB 90
- Dimensional drawing Group view
- Wiring diagram
- Product video Mains monitoring with the new DFS NU and DHS NU/NUS