Do you need help?
portrait
Your customer account manager
Marcus Häbel
Support for all products

T :
+49 4931 1806-888
E :
support at doepke dot de

residual current circuit-breaker DFS 2 025-2/0,30-HP HD

09126505HD, Residual current circuit-breakers, two-pole, 25 A, 0,3 A, for heat pumps, N left or right, HD
  • AC-DC sensitive for increased fire prevention
  • higher system availability: heat pump optimised short-time delay
  • clear labelling of the scope of application
  • "HD" design: resistant against corrosive gases and moisture
  • lower power dissipation

residual current circuit-breaker DFS 2 025-2/0,30-HP HD

09126505HD, Residual current circuit-breakers, two-pole, 25 A, 0,3 A, for heat pumps, N left or right, HD
  • AC-DC sensitive for increased fire prevention
  • higher system availability: heat pump optimised short-time delay
  • clear labelling of the scope of application
  • "HD" design: resistant against corrosive gases and moisture
  • lower power dissipation

Details

Residual current circuit-breakers, two-pole, 25 A, 0,3 A, for heat pumps, N left or right, HD

Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. Devices in the DFS 2 series are compact two-pole residual current circuit-breakers for single-phase networks. In the standard version, they only occupy two division units. The AC/DC-sensitive switches detect smooth DC residual currents and all other residual currents in accordance with DIN VDE 0664-400. Switches of the HP (Heat Pump) series have been specially developed for the protection of heat pumps. The protection level of the AC/DC sensitive residual current circuit breaker meets all requirements of heat pump manufacturers. In addition, the HP-optimised short-time delay ensures increased system availability. Devices in the standard design are intended for monitoring circuits with a rated voltage of 230 V and a rated frequency of 50 Hz. With an airtight, encapsulated tripping mechanism from a special alloy and the stainless steel latch, residual current circuit-breakers in HD design are protected, in particular from corrosion, corrosive gases, moisture and extreme temperature fluctuations.

AC/DC sensitive for residual currents with frequencies and mixed frequencies from 0 Hz to 20 kHz, fire protection according to VDE 0100-420, complete functionality with mains voltages from at least 50 V AC on any two active conductors, high short-circuit resistance, ouble-sided double-decker terminals for large conductor cross-section and busbar connection, switching position indicator, multifunction control toggle with three positions: "on", "off", "triggered", any neutral conductor position

quick fastening to mounting rail, any installation position, supply preferably from above

RCCBs of the variant HP are suitable for private, commercial and industrial installations with TN-S-, TT- and TN-C-S systems which use heat pumps.

suitable for use in 50 Hz AC networks, not intended for use on the output side of controlled electrical equipment such as frequency converters

Residual current circuit-breakers, two-pole, 25 A, 0,3 A, for heat pumps, N left or right, HD

Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. Devices in the DFS 2 series are compact two-pole residual current circuit-breakers for single-phase networks. In the standard version, they only occupy two division units. The AC/DC-sensitive switches detect smooth DC residual currents and all other residual currents in accordance with DIN VDE 0664-400. Switches of the HP (Heat Pump) series have been specially developed for the protection of heat pumps. The protection level of the AC/DC sensitive residual current circuit breaker meets all requirements of heat pump manufacturers. In addition, the HP-optimised short-time delay ensures increased system availability. Devices in the standard design are intended for monitoring circuits with a rated voltage of 230 V and a rated frequency of 50 Hz. With an airtight, encapsulated tripping mechanism from a special alloy and the stainless steel latch, residual current circuit-breakers in HD design are protected, in particular from corrosion, corrosive gases, moisture and extreme temperature fluctuations.

AC/DC sensitive for residual currents with frequencies and mixed frequencies from 0 Hz to 20 kHz, fire protection according to VDE 0100-420, complete functionality with mains voltages from at least 50 V AC on any two active conductors, high short-circuit resistance, ouble-sided double-decker terminals for large conductor cross-section and busbar connection, switching position indicator, multifunction control toggle with three positions: "on", "off", "triggered", any neutral conductor position

quick fastening to mounting rail, any installation position, supply preferably from above

RCCBs of the variant HP are suitable for private, commercial and industrial installations with TN-S-, TT- and TN-C-S systems which use heat pumps.

suitable for use in 50 Hz AC networks, not intended for use on the output side of controlled electrical equipment such as frequency converters