trip-indicating auxiliary contact DHi-S10

09917990, trip-indicating auxiliary contacts for DLS 6, 1 CO
  • Function: Auxiliary switch/Fault signalling switch
  • suitable for model range DLS 6
  • Contact assignment: 1 CO

trip-indicating auxiliary contact DHi-S10

09917990, trip-indicating auxiliary contacts for DLS 6, 1 CO
  • Function: Auxiliary switch/Fault signalling switch
  • suitable for model range DLS 6
  • Contact assignment: 1 CO

Details

trip-indicating auxiliary contacts for DLS 6, 1 CO

Auxiliary switches report the status of the main devices to which they are fitted. Fault signal auxiliary switches DHi-S can be retro-fitted to miniature circuit-breakers from series DLS 6 (h, hsl or i). The fault signal switch only activates when the miniature circuit-breaker has switched off due to overload or short-circuit. Other signal devices (buzzers, indicator light, etc.) or the Dupline bus system can then be used to indicate the operating status of the fault signal switch or for other control processes.

auxiliary switch function for DLS 6, different contact designs available, compact design (0.5 module width units), complies with IEC 60947-5-1, EN 60947-5-1 and VDE 0660-200

mounting by clamping to the right of the basic device , quick fastening to mounting rail, any installation position

These devices are suitable for querying the operating status of power supplies to residential and purpose-built buildings as well as to industrial facilities.

The auxiliary switch does not affect the function of the basic device.

trip-indicating auxiliary contacts for DLS 6, 1 CO

Auxiliary switches report the status of the main devices to which they are fitted. Fault signal auxiliary switches DHi-S can be retro-fitted to miniature circuit-breakers from series DLS 6 (h, hsl or i). The fault signal switch only activates when the miniature circuit-breaker has switched off due to overload or short-circuit. Other signal devices (buzzers, indicator light, etc.) or the Dupline bus system can then be used to indicate the operating status of the fault signal switch or for other control processes.

auxiliary switch function for DLS 6, different contact designs available, compact design (0.5 module width units), complies with IEC 60947-5-1, EN 60947-5-1 and VDE 0660-200

mounting by clamping to the right of the basic device , quick fastening to mounting rail, any installation position

These devices are suitable for querying the operating status of power supplies to residential and purpose-built buildings as well as to industrial facilities.

The auxiliary switch does not affect the function of the basic device.