automatic reclosing devices DFA 3 024DC-0

09100141, Remote actuator, 1 MW (module width), 24 V DC, RCCB: In max. 125 A, Switch-on attempts: 0
* Picture similar to the actual unit
  • Remote actuator for DFS 2/DFS 4 with up to 125 A rated current
  • 24 V, 1 module(s)
  • Number of switch-on attempts: 0

automatic reclosing devices DFA 3 024DC-0

09100141, Remote actuator, 1 MW (module width), 24 V DC, RCCB: In max. 125 A, Switch-on attempts: 0
* Picture similar to the actual unit
  • Remote actuator for DFS 2/DFS 4 with up to 125 A rated current
  • 24 V, 1 module(s)
  • Number of switch-on attempts: 0

Details

Remote actuator, 1 MW (module width), 24 V DC, RCCB: In max. 125 A, Switch-on attempts: 0

A remote actuator (ARD) is used to remotely switch connected circuit-breakers on and off. This significantly increases system availability. ARDs with an automatic function automatically switch the circuit-breaker back on. No reclosing occurs if a system error is detected. Devices from the DFA 3 series are extremely compact remote actuators for the DFS 2 and DFS 4 residual current circuit-breakers across the entire rated current range. They are available in the versions without and with three restart attempts. If the latter version recognises all attempts as unsuccessful, it blocks any further switching operations. All designs have the option of a manual switch-off and a semiconductor output, which signals the status of the flange-mounted RCCB.

retro-fittable remote actuator for Doepke residual current circuit-breakers of series DFS 2 and DFS 4, extremely compact design, installation width of 1 MW, designs without and with three activation attempts available

mounting by clamping to the left of the residual current circuit-breaker , quick fastening to mounting rail, any installation position

Remote actuators can be used anywhere where electrical installation are difficult to access or where high system availability should be achieved, This might be on agricultural premises, in small wind power stations, photovoltaic installations, charging stations for electric vehicles, pump stations, sewage treatment plants and telecommunications systems.

According to the standard, automatic restart is only permitted in areas where only trained electricians have access. The remote actuator does not affect the function of the residual current circuit-breaker.

Remote actuator, 1 MW (module width), 24 V DC, RCCB: In max. 125 A, Switch-on attempts: 0

A remote actuator (ARD) is used to remotely switch connected circuit-breakers on and off. This significantly increases system availability. ARDs with an automatic function automatically switch the circuit-breaker back on. No reclosing occurs if a system error is detected. Devices from the DFA 3 series are extremely compact remote actuators for the DFS 2 and DFS 4 residual current circuit-breakers across the entire rated current range. They are available in the versions without and with three restart attempts. If the latter version recognises all attempts as unsuccessful, it blocks any further switching operations. All designs have the option of a manual switch-off and a semiconductor output, which signals the status of the flange-mounted RCCB.

retro-fittable remote actuator for Doepke residual current circuit-breakers of series DFS 2 and DFS 4, extremely compact design, installation width of 1 MW, designs without and with three activation attempts available

mounting by clamping to the left of the residual current circuit-breaker , quick fastening to mounting rail, any installation position

Remote actuators can be used anywhere where electrical installation are difficult to access or where high system availability should be achieved, This might be on agricultural premises, in small wind power stations, photovoltaic installations, charging stations for electric vehicles, pump stations, sewage treatment plants and telecommunications systems.