00 81L 1111PPPPP90 000001 01 22.03.24 000002 02 000003 08EUR 000004 110001 N 000005 12protect 000006 21000100001NNN 00000001000Pcs 000007 25Residual current circuit-breakers, 000008 25four-pole, 40 A, 0.03 A, Type A, 000009 25Selftest Restart, N right 000010 26 Automatic restart device (ARD) with mounted residual 000011 26 current circuit-breaker (RCCB) for automatically 000012 26 switching on the residual current circuit-breaker 000013 26 again after a trip and with uninterruptible, automatic 000014 26 and regular function test for the residual current 000015 26 circuit-breaker. With automatic insulation testing 000016 26 before the restart attempt. Restart is not attempted 000017 26 if a fault is detected. Integrated, configurable 000018 26 potential-free contact and LEDs for signalling the 000019 26 operating status. With slider for 000020 26 activating/deactivating the restart function. 000021 26 doubled wiring level above and below 000022 26 switch position indicator and multifunction switch 000023 26 toggle with the functions "on", "off" and "tripped" 000024 26 (centre position) 000025 26 viewing window for labels 000026 26 000027 26 Residual current type: A 000028 26 Rated residual current IΔn: 0.03 A 000029 26 000030 26 short-time delayed (lightning-resistant) 000031 26 Neutral conductor position: right 000032 26 Module widths: 7 000033 26 Number of poles: 4 000034 26 Rated voltage (AC): 230 V, 400 V 000035 26 Rated current AC (typ.): 40 A 000036 26 Rated frequency: 50 Hz 000037 26 000038 26 auxiliary switches (semiconductor): 000039 26 Rated voltage (AC): 5 V ... 230 V 000040 26 max. Rated current AC: 0.1 A 000041 26 Rated frequency: 50 Hz 000042 26 Rated voltage (DC): 5 V ... 230 V 000043 26 max. Rated current DC: 0.1 A 000044 26 000045 26 screw-type terminal top and bottom (load circuit): 000046 26 Cross section solid: 1-wire: max. 35 mmý 000047 26 Connecting capacity flexible: 1-wire: max. 35 mmý 000048 26 000049 26 screw-type terminal bottom (auxiliary switches): 000050 26 Clamping area: max. 2.5 mmý 000051 26 Ambient temperature: min. -25 øC ... max. 60 øC 000052 26 000053 26 Housing type: distribution board housing 000054 26 Installation type: Mounting rail (35 mm) 000055 26 Protection class: IP20 (installed: IP40) 000056 26 Dimensions of transformer opening: W 124.8 mm (7 MW 000057 26 (module width)) ž H 106 mm ž D 73.5 mm 000058 26 000059 26 Design requirements/Standards: EN 50557, DIN EN 61008-1 000060 26 000061 26 Factory: Doepke or similar 000062 26 Item designation: DRCCB 5 STR 040-4/0,03-A 000063 26 Order number: 09431504 000064 26 selected make/type: ___________/___________ 000065 310001 000066 99 00001000067