00 81L 1111PPPPP90 000001 01 22.03.24 000002 02 000003 08EUR 000004 110001 N 000005 12protect 000006 21000100001NNN 00000001000Pcs 000007 25Residual current circuit-breakers, 000008 25four-pole, 16 A, 0.03 A, Type B+, 000009 25mobile installation, N right, HD 000010 26 000011 26 AC/DC sensitive residual current circuit-breakers 000012 26 (RCCBs) for detecting AC residual currents and 000013 26 pulsating and smooth DC residual currents 000014 26 sensitive to residual currents and mixed frequencies 000015 26 from 0 Hz bis 20 kHz 000016 26 The MI variant is also equipped with a tripping 000017 26 threshold of 6 mA for DC residual currents additional 000018 26 to the AC/DC sensitivity of Type B or B+. This 000019 26 prevents pre-magnetisation of upstream RCCBs type A or 000020 26 F, so that they can continue to fulfil their 000021 26 protective function. 000022 26 HD design for use in extreme environments 000023 26 doubled wiring level above and below 000024 26 switch position indicator and multifunction switch 000025 26 toggle with the functions "on", "off" and "tripped" 000026 26 (centre position) 000027 26 viewing window for labels 000028 26 000029 26 Residual current type: B+ 000030 26 Rated residual current IΔn: 0.03 A 000031 26 000032 26 short-time delayed (lightning-resistant) 000033 26 Neutral conductor position: right 000034 26 Module widths: 4 000035 26 Number of poles: 4 000036 26 Rated voltage (AC): 230 V, 400 V 000037 26 Rated current AC (typ.): 16 A 000038 26 Rated frequency: 50 Hz, 60 Hz 000039 26 000040 26 screw-type terminal top and bottom (load circuit): 000041 26 Cross section solid: 1-wire: 1.5 mmę ... 50 mmę; 000042 26 2-wire: 1.5 mmę ... 16 mmę 000043 26 Cross section stranded: 1-wire: 1.5 mmę ... 50 mmę; 000044 26 2-wire: 1.5 mmę ... 16 mmę 000045 26 Connecting capacity flexible: 1-wire: 1.5 mmę ... 50 000046 26 mmę; 2-wire: 1.5 mmę ... 16 mmę 000047 26 Cross section AWG, solid: 15 ... 1 000048 26 Cross section AWG, stranded: 15 ... 1 000049 26 Cross section AWG, flexible: 15 ... 1 000050 26 Cross section AWG, flexible with ferrule: 15 ... 1 000051 26 000052 26 Ambient temperature: min. -25 űC ... max. 60 űC 000053 26 000054 26 Housing type: distribution board housing 000055 26 Installation type: Mounting rail (35 mm) 000056 26 Protection class: IP20 (installed: IP40) 000057 26 Dimensions of transformer opening: W 72 mm (4 MW 000058 26 (module width)) ž H 85 mm ž D 75 mm 000059 26 000060 26 Design requirements/Standards: VDE 0664-10, VDE 000061 26 0664-400, ™VE/™NORM E 8601, DIN EN 61008-1 000062 26 000063 26 Factory: Doepke or similar 000064 26 Item designation: DFS 4 016-4/0,03-B+ MI R HD 000065 26 Order number: 09114890HD 000066 26 selected make/type: ___________/___________ 000067 310001 000068 99 00001000069