#begin[GAEB] #begin[GAEBInfo] [Version]1.2[end] [VersMon]3[end] [VersJahr]2002[end] [Datum]22.03.2024[end] [Uhrzeit]15:25[end] [ProgSystem]myview DataGenerator GAEB[end] [ProgName]myview-GAEB-2000-Export[end] [Zeichensatz]ANSI[end] #end[GAEBInfo] #begin[PrjInfo] [Name]Projekt[end] [Bez][end] [Wae][end] [WaeBez][end] #end[PrjInfo] #begin[Vergabe] [DP]81[end] #begin[VergabeInfo] [Wae][end] [WaeBez][end] #end[VergabeInfo] #begin[LV] #begin[LVInfo] [Name]LV[end] [Bez][end] [Datum]22.03.2024[end] [KurzLang]1[end] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]Position[end] [Laenge]3[end] #end[LVGlied] #end[LVInfo] #begin[LVBereich] [OZ]01[end] [Bez]protect[end] #begin[LVBereich] [OZ]0101[end] [Bez]fire protection switches (AFDD)[end] #begin[LVBereich] [OZ]010101[end] [Bez]Residual current type A[end] #begin[Position] [OZ]010101001[end] [Menge]1,000[end] [ME]Pcs[end] #begin[Beschreibung] [Kurztext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Fire protection switch, two-pole, 10 A, 0.03 A, C-characteristic, Type A [Langtext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Residual current operated circuit-breaker with integral overcurrent protection (RCBO) and arc fault detection (fire protection switch)\par The device is designed for detecting AC residual currents and pulsating DC residual currents and arc faults.\par \par Tripping characteristic: C\par \par Residual current type: A\par Rated residual current IΔn: 0.03 A\par Neutral conductor position: left, right\par Module widths: 3\par \par load circuit (load disconnect contact):\par Number of poles: 2\par Rated voltage (AC): 240 V\par Rated current AC (typ.): 10 A \par Rated frequency: 50 Hz\par max. Total rated switching capacity: 10 kA\par Rated insulation voltage: 250 V\par \par screw-type terminal top, bottom (load circuit):\par max. Cable length: 70 m\par Clamping area: min. 1 mm² ... max. 25 mm²\par Ambient temperature: min. -25 °C ... max. 40 °C\par \par Housing type: distribution board housing\par Installation type: Mounting rail (35 mm)\par Protection class: IP20 (installed: IP40)\par Dimensions of transformer opening: W 54 mm (3 MW (module width)) × H 80 mm × D 76 mm\par \par Certifications: VDE\par Design requirements/Standards: EN 62606, EN 61009\par \par Factory: Doepke or similar\par Item designation: DAFDD 1 C10/0,03/2-A\par Order number: 09962102\par selected make/type: ___________/___________ #end[Beschreibung] #end[Position] #end[LVBereich] #end[LVBereich] #end[LVBereich] #end[LV] #end[Vergabe] #end[GAEB]