#begin[GAEB] #begin[GAEBInfo] [Version]1.2[end] [VersMon]3[end] [VersJahr]2002[end] [Datum]22.03.2024[end] [Uhrzeit]15:25[end] [ProgSystem]myview DataGenerator GAEB[end] [ProgName]myview-GAEB-2000-Export[end] [Zeichensatz]ANSI[end] #end[GAEBInfo] #begin[PrjInfo] [Name]Projekt[end] [Bez][end] [Wae][end] [WaeBez][end] #end[PrjInfo] #begin[Vergabe] [DP]81[end] #begin[VergabeInfo] [Wae][end] [WaeBez][end] #end[VergabeInfo] #begin[LV] #begin[LVInfo] [Name]LV[end] [Bez][end] [Datum]22.03.2024[end] [KurzLang]1[end] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]Position[end] [Laenge]3[end] #end[LVGlied] #end[LVInfo] #begin[LVBereich] [OZ]01[end] [Bez]protect[end] #begin[LVBereich] [OZ]0101[end] [Bez]residual current operated circuit-breakers with integral overcurrent protection (RCBOs)[end] #begin[LVBereich] [OZ]010101[end] [Bez]Residual current type F[end] #begin[Position] [OZ]010101001[end] [Menge]1,000[end] [ME]Pcs[end] #begin[Beschreibung] [Kurztext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Residual current operated circuit-breaker with integral overcurrent protection, one-pole+N, 13 A, 0.1 A, C-characteristic, Type F, short-time delayed [Langtext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Mains voltage-independent residual current circuit-breaker with overcurrent protection (RCBO) for detecting AC residual currents and pulsating DC residual currents\par sensitive to residual currents and mixed frequencies from 10 Hz to 1 kHz when using single-phase electronic consumers\par suitable for retro-fitting of additional equipment\par \par Tripping characteristic: C\par Residual current type: F\par Rated residual current IΔn: 0.1 A\par \par short-time delayed (lightning-resistant)\par Neutral conductor position: right\par Module widths: 2\par \par load circuit (load disconnect contact):\par Number of poles: 2\par Rated voltage (AC): 230 V\par Rated current AC (typ.): 13 A \par Rated frequency: 50 Hz\par max. Total rated switching capacity: 10 kA\par Rated insulation voltage: 440 V\par \par screw-type terminal top, bottom (load circuit):\par Cross section solid: 1-wire: 1 mm² ... 25 mm²\par Cross section stranded: 1-wire: 1 mm² ... 16 mm²\par Connecting capacity flexible: 1-wire: 1 mm² ... 16 mm²\par Ambient temperature: min. -25 °C ... max. 40 °C\par \par Housing type: distribution board housing\par Installation type: Mounting rail (35 mm)\par Protection class: IP20 (installed: IP40)\par Dimensions of transformer opening: W 35 mm (2 MW (module width)) × H 80 mm × D 74 mm\par \par \par Factory: Doepke or similar\par Item designation: DRCBO 3 C13/0,10/1N-F\par Order number: 09932373\par selected make/type: ___________/___________ #end[Beschreibung] #end[Position] #end[LVBereich] #end[LVBereich] #end[LVBereich] #end[LV] #end[Vergabe] #end[GAEB]