#begin[GAEB] #begin[GAEBInfo] [Version]1.2[end] [VersMon]3[end] [VersJahr]2002[end] [Datum]22.03.2024[end] [Uhrzeit]15:21[end] [ProgSystem]myview DataGenerator GAEB[end] [ProgName]myview-GAEB-2000-Export[end] [Zeichensatz]ANSI[end] #end[GAEBInfo] #begin[PrjInfo] [Name]Projekt[end] [Bez][end] [Wae][end] [WaeBez][end] #end[PrjInfo] #begin[Vergabe] [DP]81[end] #begin[VergabeInfo] [Wae][end] [WaeBez][end] #end[VergabeInfo] #begin[LV] #begin[LVInfo] [Name]LV[end] [Bez][end] [Datum]22.03.2024[end] [KurzLang]1[end] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]Position[end] [Laenge]3[end] #end[LVGlied] #end[LVInfo] #begin[LVBereich] [OZ]01[end] [Bez]protect[end] #begin[LVBereich] [OZ]0101[end] [Bez]Residual current circuit-breakers (RCCBs)[end] #begin[LVBereich] [OZ]010101[end] [Bez]Residual current type A[end] #begin[Position] [OZ]010101001[end] [Menge]1,000[end] [ME]Pcs[end] #begin[Beschreibung] [Kurztext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Residual current circuit-breakers, two-pole, 25 A, 0.03 A, Type A, Selftest, N right [Langtext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Residual current circuit-breaker (RCCB) with uninterruptible, automatic and regular function test for the residual current circuit-breaker. The self-test is performed monthly. LEDs and a configurable auxiliary contact signal that the self-test is ready. The self-test can be switched on or off using a simple slider.\par doubled wiring level above and below\par switch position indicator and multifunction switch toggle with the functions "on", "off" and "tripped" (centre position)\par viewing window for labels\par \par Residual current type: A\par Rated residual current IΔn: 0.03 A\par \par short-time delayed (lightning-resistant)\par Neutral conductor position: right\par Module widths: 5\par Number of poles: 2\par Rated voltage (AC): 230 V\par Rated current AC (typ.): 25 A\par Rated frequency: 50 Hz\par \par auxiliary switches (semiconductor):\par Rated voltage (AC): 5 V ... 230 V \par max. Rated current AC: 0.1 A\par Rated frequency: 50 Hz\par Rated voltage (DC): 5 V ... 230 V\par max. Rated current DC: 0.1 A\par \par screw-type terminal top and bottom (load circuit):\par Cross section solid: 1-wire: max. 35 mm²\par Connecting capacity flexible: 1-wire: max. 35 mm²\par \par screw-type terminal bottom (auxiliary switches):\par Clamping area: max. 2.5 mm²\par Ambient temperature: min. -25 °C ... max. 60 °C\par \par Housing type: distribution board housing\par Installation type: Mounting rail (35 mm)\par Protection class: IP20 (installed: IP40)\par Dimensions of transformer opening: W 90 mm (5 MW (module width)) × H 106 mm × D 73.5 mm\par \par Certifications: VDE\par Design requirements/Standards: DIN EN 61008-1, VDE 0664-120 (Annex M)\par \par Factory: Doepke or similar\par Item designation: DRCCB 5 ST 025-2/0,03-A\par Order number: 09421501\par selected make/type: ___________/___________ #end[Beschreibung] #end[Position] #end[LVBereich] #end[LVBereich] #end[LVBereich] #end[LV] #end[Vergabe] #end[GAEB]