#begin[GAEB] #begin[GAEBInfo] [Version]1.2[end] [VersMon]3[end] [VersJahr]2002[end] [Datum]22.03.2024[end] [Uhrzeit]15:27[end] [ProgSystem]myview DataGenerator GAEB[end] [ProgName]myview-GAEB-2000-Export[end] [Zeichensatz]ANSI[end] #end[GAEBInfo] #begin[PrjInfo] [Name]Projekt[end] [Bez][end] [Wae][end] [WaeBez][end] #end[PrjInfo] #begin[Vergabe] [DP]81[end] #begin[VergabeInfo] [Wae][end] [WaeBez][end] #end[VergabeInfo] #begin[LV] #begin[LVInfo] [Name]LV[end] [Bez][end] [Datum]22.03.2024[end] [KurzLang]1[end] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]Position[end] [Laenge]3[end] #end[LVGlied] #end[LVInfo] #begin[LVBereich] [OZ]01[end] [Bez]monitor[end] #begin[LVBereich] [OZ]0101[end] [Bez]residual current monitors (RCM)[end] #begin[LVBereich] [OZ]010101[end] [Bez]Residual current type A[end] #begin[Position] [OZ]010101001[end] [Menge]1,000[end] [ME]Pcs[end] #begin[Beschreibung] [Kurztext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Residual current monitor, 4\u8211?20 mA interface, Type A, 20 mm [Langtext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Residual current monitors with integrated bushing transformer for continuous detection of sinusoidal AC and pulsating DC currents.\par Signals the transgression of the response threshold of 50% of the rated residual current by the integrated relay.\par Signals the transgression of the response threshold of 50% of the rated residual current by the integrated relay\par Output of the instantaneous residual current via standardised 4-20 mA interface for optional indication and monitoring\par \par Residual operating current characteristics: A\par max. adjustable residual operating current I\u8710?adj AC: \par Frequency range response residual current Type A: 50 Hz ... 60 Hz\par voltage type of monitored circuit: AC\par Rated voltage Uem of circuit monitored AC: 0 V ... 690 V\par Rated frequency of circuit monitored: 50 Hz ... 60 Hz\par Control elements: test key\par \par transformer, primary side:\par Rated current: 200 A\par Rated impulse withstand voltage: 8 kV\par \par alarm output (relays):\par 1 CO\par Rated voltage (AC): 30 V (27 V ... 33 V)\par Rated current AC (typ.): 1 A \par Rated voltage (DC): 30 V (27 V ... 33 V)\par Rated current DC (typ.): 1 A\par \par 4\u8211?20 mA interface (semiconductor): \par \par Operating voltage (DC): 24 V (21.6 V ... 26.4 V)\par \par Housing type: wall-mounted housing\par Installation type: Wall mounting\par Protection class: IP20\par Dimensions of transformer opening: W 70 mm × H 84 mm × D 66 mm\par Inside diameter: 20 mm\par \par Design requirements/Standards: DIN EN 62020, DIN EN 61000-4-3, DIN EN 61000-4-6, DIN IEC 381-1, ISA-50.1\par \par Factory: Doepke or similar\par Item designation: DCTR A 020/0,30-I\par Order number: 09342621\par selected make/type: ___________/___________ #end[Beschreibung] #end[Position] #end[LVBereich] #end[LVBereich] #end[LVBereich] #end[LV] #end[Vergabe] #end[GAEB]