#begin[GAEB] #begin[GAEBInfo] [Version]1.2[end] [VersMon]3[end] [VersJahr]2002[end] [Datum]22.03.2024[end] [Uhrzeit]15:27[end] [ProgSystem]myview DataGenerator GAEB[end] [ProgName]myview-GAEB-2000-Export[end] [Zeichensatz]ANSI[end] #end[GAEBInfo] #begin[PrjInfo] [Name]Projekt[end] [Bez][end] [Wae][end] [WaeBez][end] #end[PrjInfo] #begin[Vergabe] [DP]81[end] #begin[VergabeInfo] [Wae][end] [WaeBez][end] #end[VergabeInfo] #begin[LV] #begin[LVInfo] [Name]LV[end] [Bez][end] [Datum]22.03.2024[end] [KurzLang]1[end] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]Position[end] [Laenge]3[end] #end[LVGlied] #end[LVInfo] #begin[LVBereich] [OZ]01[end] [Bez]protect[end] #begin[LVBereich] [OZ]0101[end] [Bez]Circuit-breakers with residual current protection (CBR)[end] #begin[LVBereich] [OZ]010101[end] [Bez]Residual current type A[end] #begin[Position] [OZ]010101001[end] [Menge]1,000[end] [ME]Pcs[end] #begin[Beschreibung] [Kurztext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Circuit-breakers with integral residual current protection, 4-pole, 160 A, 0.03 A, Type A, 60 Hz [Langtext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Circuit-breakers with residual current trip (CBR), 4-pole, compact design, with contact system limited by short-circuit current, with adjustable thermomagnetic trips, with rocker arm and 3 switch positions (off, tripped and on), as per IEC/EN 60947-2, DIN VDE 0660\par \par Residual current type: A\par Rated residual current IΔn: 0.03 A\par \par short-time delayed (lightning-resistant)\par Neutral conductor position: left\par Rated operating voltage: 690 V AC\par Operating frequency: 60 Hz\par Rated impulse withstand voltage: 8 kV\par Rated continuous current: 160 A\par Rated short-circuit disconnecting capacity (690 V AC): 20 kA\par Operating voltage: min. -25 °C ... max. 70 °C\par Mechanical endurance: 2000 switching cycles\par Electrical endurance AC-1: 7500 cycles\par Overload trip: 0.8 - 1 x Ir\par Instantaneous short-circuit trip Ii: 6 - 10 x Iu\par Integrated auxiliary switch: 1 NO, 1 NC, 0 CO\par \par \par box terminal top and bottom (load circuit):\par Clamping area: min. 4 mm² ... max. 185 mm²\par Cross section solid: 1-wire: 4 mm² ... 16 mm²; 2-wire: 4 mm² ... 16 mm²\par Cross section stranded: 1-wire: 25 mm² ... 185 mm²; 2-wire: 25 mm² ... 70 mm²\par \par \par Housing type: wall-mounted housing\par Installation type: Wall mounting\par Protection class: IP20 (installed: IP40)\par Dimensions of transformer opening: W 140 mm × H 291 mm × D 103 mm\par \par \par Design requirements/Standards: DIN IEC 60755, EN 60947-2, EN 60947-2 Annex B, VDE 0660-101\par \par Factory: Doepke or similar\par Item designation: DFL 8 160-4/0,03-A Hz60\par Order number: 09184790\par selected make/type: ___________/___________ #end[Beschreibung] #end[Position] #end[LVBereich] #end[LVBereich] #end[LVBereich] #end[LV] #end[Vergabe] #end[GAEB]