#begin[GAEB] #begin[GAEBInfo] [Version]1.2[end] [VersMon]3[end] [VersJahr]2002[end] [Datum]22.03.2024[end] [Uhrzeit]15:21[end] [ProgSystem]myview DataGenerator GAEB[end] [ProgName]myview-GAEB-2000-Export[end] [Zeichensatz]ANSI[end] #end[GAEBInfo] #begin[PrjInfo] [Name]Projekt[end] [Bez][end] [Wae][end] [WaeBez][end] #end[PrjInfo] #begin[Vergabe] [DP]81[end] #begin[VergabeInfo] [Wae][end] [WaeBez][end] #end[VergabeInfo] #begin[LV] #begin[LVInfo] [Name]LV[end] [Bez][end] [Datum]22.03.2024[end] [KurzLang]1[end] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]Position[end] [Laenge]3[end] #end[LVGlied] #end[LVInfo] #begin[LVBereich] [OZ]01[end] [Bez]protect[end] #begin[LVBereich] [OZ]0101[end] [Bez]Residual current circuit-breakers (RCCBs)[end] #begin[LVBereich] [OZ]010101[end] [Bez]Residual current type AC[end] #begin[Position] [OZ]010101001[end] [Menge]1,000[end] [ME]Pcs[end] #begin[Beschreibung] [Kurztext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Residual current circuit-breakers, two-pole, 63 A, 0.5 A, Type AC, for point heaters, N left or right [Langtext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 \par Mains voltage independent RCCB for detection of AC residual currents (not admitted for use in Germany)\par for use in earthed power networks for tracks, e. g. point heater systems with a rated frequency of 16 2/3 Hz and voltages up to 500 V\par doubled wiring level above and below\par switch position indicator and multifunction switch toggle with the functions "on", "off" and "tripped" (centre position)\par viewing window for labels\par \par Residual current type: AC\par Rated residual current IΔn: 0.5 A\par Neutral conductor position: left or right\par Module widths: 4\par Number of poles: 2\par Rated voltage (AC): 290 V, 500 V\par Rated current AC (typ.): 63 A\par Rated frequency: 16.67 Hz ... 60 Hz \par \par screw-type terminal top and bottom (load circuit):\par Cross section solid: 1-wire: 1.5 mm² ... 50 mm²; 2-wire: 1.5 mm² ... 16 mm²\par Cross section stranded: 1-wire: 1.5 mm² ... 50 mm²; 2-wire: 1.5 mm² ... 16 mm²\par Connecting capacity flexible: 1-wire: 1.5 mm² ... 50 mm²; 2-wire: 1.5 mm² ... 16 mm²\par Cross section AWG, solid: 15 ... 1\par Cross section AWG, stranded: 15 ... 1\par Cross section AWG, flexible: 15 ... 1\par Cross section AWG, flexible with ferrule: 15 ... 1\par \par Ambient temperature: min. -25 °C ... max. 40 °C\par \par Housing type: distribution board housing\par Installation type: Mounting rail (35 mm)\par Protection class: IP20 (installed: IP40)\par Dimensions of transformer opening: W 72 mm (4 MW (module width)) × H 85 mm × D 75 mm\par \par Design requirements/Standards: VDE 0664-10, DIN EN 61008-1\par \par Factory: Doepke or similar\par Item designation: DFS 4W 063-2/0,50-AC\par Order number: 09147962\par selected make/type: ___________/___________ #end[Beschreibung] #end[Position] #end[LVBereich] #end[LVBereich] #end[LVBereich] #end[LV] #end[Vergabe] #end[GAEB]