#begin[GAEB] #begin[GAEBInfo] [Version]1.2[end] [VersMon]3[end] [VersJahr]2002[end] [Datum]22.03.2024[end] [Uhrzeit]15:20[end] [ProgSystem]myview DataGenerator GAEB[end] [ProgName]myview-GAEB-2000-Export[end] [Zeichensatz]ANSI[end] #end[GAEBInfo] #begin[PrjInfo] [Name]Projekt[end] [Bez][end] [Wae][end] [WaeBez][end] #end[PrjInfo] #begin[Vergabe] [DP]81[end] #begin[VergabeInfo] [Wae][end] [WaeBez][end] #end[VergabeInfo] #begin[LV] #begin[LVInfo] [Name]LV[end] [Bez][end] [Datum]22.03.2024[end] [KurzLang]1[end] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]Position[end] [Laenge]3[end] #end[LVGlied] #end[LVInfo] #begin[LVBereich] [OZ]01[end] [Bez]protect[end] #begin[LVBereich] [OZ]0101[end] [Bez]Residual current circuit-breakers (RCCBs)[end] #begin[LVBereich] [OZ]010101[end] [Bez]Residual current type A[end] #begin[Position] [OZ]010101001[end] [Menge]1,000[end] [ME]Pcs[end] #begin[Beschreibung] [Kurztext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Residual current circuit-breakers, four-pole, 40 A, 0.3 A, Type A, with remote-tripping function, N left [Langtext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Mains voltage-independent residual current circuit-breaker (RCCB) for detecting AC residual currents and pulsating DC residual currents\par with an additional signalling contact and terminals switched in parallel to the test key for activating the test device using external switching contacts\par doubled wiring level above and below\par switch position indicator and multifunction switch toggle with the functions "on", "off" and "tripped" (centre position)\par viewing window for labels\par \par Residual current type: A\par Rated residual current IΔn: 0.3 A\par Neutral conductor position: left\par Module widths: 4.5\par Number of poles: 4\par Rated voltage (AC): 230 V, 400 V\par Rated current AC (typ.): 40 A\par Rated frequency: 50 Hz\par \par remote trip (switching contact):\par 1 NC\par Rated current AC (typ.): 6 A \par Rated current DC (typ.): 1 A\par \par control input:\par Rated voltage (AC): 400 V\par \par screw-type terminal top and bottom (load circuit):\par Cross section solid: 1-wire: 1.5 mm² ... 50 mm²; 2-wire: 1.5 mm² ... 16 mm²\par Cross section stranded: 1-wire: 1.5 mm² ... 50 mm²; 2-wire: 1.5 mm² ... 16 mm²\par Connecting capacity flexible: 1-wire: 1.5 mm² ... 50 mm²; 2-wire: 1.5 mm² ... 16 mm²\par Cross section AWG, solid: 15 ... 1\par Cross section AWG, stranded: 15 ... 1\par Cross section AWG, flexible: 15 ... 1\par Cross section AWG, flexible with ferrule: 15 ... 1\par \par screw-type terminal top, bottom (remote trip):\par Cross section solid: 1-wire: 1 mm² ... 1.5 mm²; 2-wire: 1 mm² ... 1.5 mm²\par Cross section stranded: 1-wire: 1 mm² ... 1.5 mm²; 2-wire: 1 mm² ... 1.5 mm²\par Cross section flexible with ferrule: 1 mm² ... 1.5 mm²\par Cross section AWG, solid: 17 ... 16\par Cross section AWG, stranded: 17 ... 16\par Cross section AWG, flexible with ferrule: 17 ... 16\par Ambient temperature: min. -25 °C ... max. 40 °C\par \par Housing type: distribution board housing\par Installation type: Mounting rail (35 mm)\par Protection class: IP20 (installed: IP40)\par Dimensions of transformer opening: W 81 mm (4.5 MW (module width)) × H 85 mm × D 75 mm\par \par Design requirements/Standards: VDE 0664-10, DIN EN 61008-1\par \par Factory: Doepke or similar\par Item designation: DFS 4 040-4/0,30-A FT\par Order number: 09136921\par selected make/type: ___________/___________ #end[Beschreibung] #end[Position] #end[LVBereich] #end[LVBereich] #end[LVBereich] #end[LV] #end[Vergabe] #end[GAEB]