#begin[GAEB] #begin[GAEBInfo] [Version]1.2[end] [VersMon]3[end] [VersJahr]2002[end] [Datum]22.03.2024[end] [Uhrzeit]15:20[end] [ProgSystem]myview DataGenerator GAEB[end] [ProgName]myview-GAEB-2000-Export[end] [Zeichensatz]ANSI[end] #end[GAEBInfo] #begin[PrjInfo] [Name]Projekt[end] [Bez][end] [Wae][end] [WaeBez][end] #end[PrjInfo] #begin[Vergabe] [DP]81[end] #begin[VergabeInfo] [Wae][end] [WaeBez][end] #end[VergabeInfo] #begin[LV] #begin[LVInfo] [Name]LV[end] [Bez][end] [Datum]22.03.2024[end] [KurzLang]1[end] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]LVStufe[end] [Laenge]2[end] #end[LVGlied] #begin[LVGlied] [Typ]Position[end] [Laenge]3[end] #end[LVGlied] #end[LVInfo] #begin[LVBereich] [OZ]01[end] [Bez]protect[end] #begin[LVBereich] [OZ]0101[end] [Bez]Residual current circuit-breakers (RCCBs)[end] #begin[LVBereich] [OZ]010101[end] [Bez]Residual current type A[end] #begin[Position] [OZ]010101001[end] [Menge]1,000[end] [ME]Pcs[end] #begin[Beschreibung] [Kurztext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Residual current circuit-breakers, four-pole, 25 A, 0.03 A, Type A, with emergency shut-off function, N left [Langtext]{\rtf1\ansi\deff0{\fonttbl\f0\fmodern Arial;}\uc1 Mains voltage-independent residual current circuit-breaker (RCCB) for detecting AC residual currents and pulsating DC residual currents\par Integrated emergency shut-off device for tripping or disconnection in emergency situations with signalling by LED, wire breakage detection and the possibility of parallel switching of multiple DFS in NA design\par \par doubled wiring level above and below\par switch position indicator and multifunction switch toggle with the functions "on", "off" and "tripped" (centre position)\par viewing window for labels\par \par Residual current type: A\par Rated residual current IΔn: 0.03 A\par Neutral conductor position: left\par Module widths: 4.5\par Number of poles: 4\par Rated voltage (AC): 230 V, 400 V\par Rated current AC (typ.): 25 A\par Rated frequency: 50 Hz\par \par Auxiliary switch (additional emergency shut-off device) (switching contact):\par 1 CO\par Rated voltage (AC): 12 V ... 230 V \par Rated voltage (DC): 12 V ... 110 V\par \par screw-type terminal top and bottom (load circuit):\par Cross section solid: 1-wire: 1.5 mm² ... 50 mm²; 2-wire: 1.5 mm² ... 16 mm²\par Cross section stranded: 1-wire: 1.5 mm² ... 50 mm²; 2-wire: 1.5 mm² ... 16 mm²\par Connecting capacity flexible: 1-wire: 1.5 mm² ... 50 mm²; 2-wire: 1.5 mm² ... 16 mm²\par Cross section AWG, solid: 15 ... 1\par Cross section AWG, stranded: 15 ... 1\par Cross section AWG, flexible: 15 ... 1\par Cross section AWG, flexible with ferrule: 15 ... 1\par \par screw-type terminal top and bottom (Emergency shut-off device, auxiliary switches):\par Cross section solid: 1-wire: 1 mm² ... 1.5 mm²; 2-wire: 1 mm² ... 1.5 mm²\par Cross section stranded: 1-wire: 1 mm² ... 1.5 mm²; 2-wire: 1 mm² ... 1.5 mm²\par Cross section flexible with ferrule: 1 mm² ... 1.5 mm²\par Cross section AWG, solid: 17 ... 16\par Cross section AWG, stranded: 17 ... 16\par Cross section AWG, flexible with ferrule: 17 ... 16\par Ambient temperature: min. -25 °C ... max. 40 °C\par \par Housing type: distribution board housing\par Installation type: Mounting rail (35 mm)\par Protection class: IP20 (installed: IP40)\par Dimensions of transformer opening: W 81 mm (4.5 MW (module width)) × H 85 mm × D 75 mm\par \par Design requirements/Standards: VDE 0664-10, VDE V 0664-120, DIN EN 61008-1\par \par Factory: Doepke or similar\par Item designation: DFS 4 025-4/0,03-A NA\par Order number: 09124841\par selected make/type: ___________/___________ #end[Beschreibung] #end[Position] #end[LVBereich] #end[LVBereich] #end[LVBereich] #end[LV] #end[Vergabe] #end[GAEB]