Do you need help?
portrait
Your customer account manager
Marcus Häbel
Support for all products

T :
+49 4931 1806-888
E :
support at doepke dot de

twilight switches EDS 16 mit LF 1

09500110, Twilight switches, 230 V AC, with light sensor, REG
  • activates the lighting depending on brightness
  • Light sensor LF 1 included
  • 2 lux ... 1000 lux
  • for mounting in the distribution board, outdoor sensors
  • Operating voltage (AC): 230 V (207 V ... 253 V)

twilight switches EDS 16 mit LF 1

09500110, Twilight switches, 230 V AC, with light sensor, REG
  • activates the lighting depending on brightness
  • Light sensor LF 1 included
  • 2 lux ... 1000 lux
  • for mounting in the distribution board, outdoor sensors
  • Operating voltage (AC): 230 V (207 V ... 253 V)

Details

Twilight switches, 230 V AC, with light sensor, REG

Twilight switches switch on electrical consumers when it turns dark and switch them off again when it turns light. The twilight switches of this series are devices for distribution board installation with an external light sensor. It is possible to install the switch and external light sensor anywhere, regardless of the lighting to be switched; the distribution board easily handles the settings for the switch-on/switch-off thresholds. The operating and control voltage of the devices is 230 V AC. The EDS 16 compares the current illuminance with the set switch-on threshold. If the illuminance reaches the desired switch-on threshold, a delay time starts. Once the delay time has expired the load relay of the twilight switch is switched on. If the switch-off threshold is reached due to increasing illuminance, the relay switches off again after the delay time has expired. The slow switching responses prevent unnecessary switch-on or dangerous switch-off when the brightness changes briefly (e.g. due to lightning and car headlights).

energy saving thanks to automatic lighting control, switch-on/switch-off delay mutes brief fluctuations in brightness, low internal consumption, easy mounting and adjustment , adjustable switch-on threshold of 2 to 1000 lux, switch-off threshold prescribed by internal factor 1.5, potential-free NO contact (16 A), switch-on/relay status indicated by LED , LF 1 light sensors for outdoor mounting (IP44), cable length to LF 1 up to 100 m , more than one twilight switch can use one LF 1.

Twilight switch: quick fastening to mounting rail, any installation position Light sensor LF 1: , Wall mounting, preferably facing north or east

Control of lighting for streets, buildings and industrial premises.

Depending on the order number, the twilight switch is supplied with or without a light sensor.

Twilight switches, 230 V AC, with light sensor, REG

Twilight switches switch on electrical consumers when it turns dark and switch them off again when it turns light. The twilight switches of this series are devices for distribution board installation with an external light sensor. It is possible to install the switch and external light sensor anywhere, regardless of the lighting to be switched; the distribution board easily handles the settings for the switch-on/switch-off thresholds. The operating and control voltage of the devices is 230 V AC. The EDS 16 compares the current illuminance with the set switch-on threshold. If the illuminance reaches the desired switch-on threshold, a delay time starts. Once the delay time has expired the load relay of the twilight switch is switched on. If the switch-off threshold is reached due to increasing illuminance, the relay switches off again after the delay time has expired. The slow switching responses prevent unnecessary switch-on or dangerous switch-off when the brightness changes briefly (e.g. due to lightning and car headlights).

energy saving thanks to automatic lighting control, switch-on/switch-off delay mutes brief fluctuations in brightness, low internal consumption, easy mounting and adjustment , adjustable switch-on threshold of 2 to 1000 lux, switch-off threshold prescribed by internal factor 1.5, potential-free NO contact (16 A), switch-on/relay status indicated by LED , LF 1 light sensors for outdoor mounting (IP44), cable length to LF 1 up to 100 m , more than one twilight switch can use one LF 1.

Twilight switch: quick fastening to mounting rail, any installation position Light sensor LF 1: , Wall mounting, preferably facing north or east

Control of lighting for streets, buildings and industrial premises.

Depending on the order number, the twilight switch is supplied with or without a light sensor.