residual current operated circuit-breakers with integral overcurrent protection FIB 06/0,03/3+N-B NK

09958201, Residual current operated circuit-breaker with integral overcurrent protection, three-pole+N, 6 A, 0,03 A, B-characteristic, Type B, short-time delayed
* Picture similar to the actual unit
Discontinued product - Please ask for availability
  • AC-DC sensitive up to 150 kHz
  • higher system availability: short-time delayed
Discontinued

residual current operated circuit-breakers with integral overcurrent protection FIB 06/0,03/3+N-B NK

09958201, Residual current operated circuit-breaker with integral overcurrent protection, three-pole+N, 6 A, 0,03 A, B-characteristic, Type B, short-time delayed
* Picture similar to the actual unit
Discontinued product - Please ask for availability
  • AC-DC sensitive up to 150 kHz
  • higher system availability: short-time delayed

Details

Residual current operated circuit-breaker with integral overcurrent protection, three-pole+N, 6 A, 0,03 A, B-characteristic, Type B, short-time delayed

RCBOs combine residual current and miniature circuit-breakers in a single device (RCBO). They protect people against residual currents and systems against short-circuit and overload. The FIB/FIC residual current operated circuit-breakers with integral overcurrent protection have a rated switching capacity of 6 kA. A tripping indicator and label window facilitate the overview. Type B switches are AC-DC sensitive at frequencies of 0 Hz (smooth residual currents) to 150 kHz. They have increased resistance to surge currents and lightning. Switches with the characteristic curve NK provide classic fire protection of 300 mA at frequencies up to 150 kHz. They are optimised for facilities at risk of fire. Switches with tripping characteristic B are the standard protection for lighting and socket circuits. Standard switches are designed for electric circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz.

AC/DC sensitive for residual currents with frequencies of 0 Hz (smooth direct current) up to 150 kHz, mains-voltage-independent tripping when type A residual currents occur, compact design for all rated currents, switch position indicator, separate indication of tripping cause, strain-relief clamps with a wide terminal cross-section range on both connection sides, neutral conductor right, labelling area

quick fastening to mounting rail, any installation position, supply preferably from above

commercial and industrial installations with TT, TN-S and TN-C-S systems, where power electronics equipment is used without galvanic isolation from the mains, e.g. frequency converters, switching power supplies, high-frequency converters, photovoltaic installations and UPS equipment with frequency converters without transformers, Type B+ and type B RCBOs with characteristic curve NK should be used where fire protection is legally required.

suitable for use in 50 Hz AC networks, RCBOs are also available for other frequencies upon request, not designed for use in direct current networks or on the output side of controlled electrical equipment such as frequency converters

Residual current operated circuit-breaker with integral overcurrent protection, three-pole+N, 6 A, 0,03 A, B-characteristic, Type B, short-time delayed

RCBOs combine residual current and miniature circuit-breakers in a single device (RCBO). They protect people against residual currents and systems against short-circuit and overload. The FIB/FIC residual current operated circuit-breakers with integral overcurrent protection have a rated switching capacity of 6 kA. A tripping indicator and label window facilitate the overview. Type B switches are AC-DC sensitive at frequencies of 0 Hz (smooth residual currents) to 150 kHz. They have increased resistance to surge currents and lightning. Switches with the characteristic curve NK provide classic fire protection of 300 mA at frequencies up to 150 kHz. They are optimised for facilities at risk of fire. Switches with tripping characteristic B are the standard protection for lighting and socket circuits. Standard switches are designed for electric circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz.

AC/DC sensitive for residual currents with frequencies of 0 Hz (smooth direct current) up to 150 kHz, mains-voltage-independent tripping when type A residual currents occur, compact design for all rated currents, switch position indicator, separate indication of tripping cause, strain-relief clamps with a wide terminal cross-section range on both connection sides, neutral conductor right, labelling area

quick fastening to mounting rail, any installation position, supply preferably from above

commercial and industrial installations with TT, TN-S and TN-C-S systems, where power electronics equipment is used without galvanic isolation from the mains, e.g. frequency converters, switching power supplies, high-frequency converters, photovoltaic installations and UPS equipment with frequency converters without transformers, Type B+ and type B RCBOs with characteristic curve NK should be used where fire protection is legally required.

suitable for use in 50 Hz AC networks, RCBOs are also available for other frequencies upon request, not designed for use in direct current networks or on the output side of controlled electrical equipment such as frequency converters