residual current operated circuit-breakers with integral overcurrent protection RCBO 2 C10/0,03/2-A


residual current operated circuit-breakers with integral overcurrent protection RCBO 2 C10/0,03/2-A
Details
Residual current operated circuit-breaker with integral overcurrent protection, two-pole, 10 A, 0,03 A, 6 kA, C-characteristic, Type A
RCBOs combine residual current protection and overcurrent protection in a single device. This makes them ideal for use in distribution boards where space is limited. The rated breaking capacity of the two-pole RCBO 2 series is 6 kA. Type A circuit-breakers detect pulsating direct current and alternating current. With tripping characteristic C, these circuit-breakers ensure reliable protection for your circuits with loads that generate higher inrush peaks. Standard circuit-breakers are designed for circuits with 230 V or 400 V at 50 Hz.
Mains-voltage-independent tripping, compact design for all rated currents, high short-circuit resistance, Residual current tripping indicator, Strain-relief clamps with protection against wires being lodged behind them and wide terminal cross-section range for rail and line wiring on both connection sides, Use of conventional wiring rails possible, Neutral conductor right, bi-stable snap-in slider for easy mounting and removal
quick fastening to mounting rail, any installation position, supply as desired
Power supplies to residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the RCBOs of this series can be set to switch off in the event of a second fault, Not permitted for use in TN-C networks and for protecting systems in which electronic equipment may cause pulsating or smooth DC residual currents or residual currents with frequencies not equal to 50 Hz. Comprehensive protection is not provided with an RCCB type AC. For these applications we recommend our residual current operated circuit-breakers with integral overcurrent protection Type A or our AC-DC sensitive RCBO Type B.
Residual current operated circuit-breaker with integral overcurrent protection, two-pole, 10 A, 0,03 A, 6 kA, C-characteristic, Type A
RCBOs combine residual current protection and overcurrent protection in a single device. This makes them ideal for use in distribution boards where space is limited. The rated breaking capacity of the two-pole RCBO 2 series is 6 kA. Type A circuit-breakers detect pulsating direct current and alternating current. With tripping characteristic C, these circuit-breakers ensure reliable protection for your circuits with loads that generate higher inrush peaks. Standard circuit-breakers are designed for circuits with 230 V or 400 V at 50 Hz.
Mains-voltage-independent tripping, compact design for all rated currents, high short-circuit resistance, Residual current tripping indicator, Strain-relief clamps with protection against wires being lodged behind them and wide terminal cross-section range for rail and line wiring on both connection sides, Use of conventional wiring rails possible, Neutral conductor right, bi-stable snap-in slider for easy mounting and removal
quick fastening to mounting rail, any installation position, supply as desired
Power supplies to residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the RCBOs of this series can be set to switch off in the event of a second fault, Not permitted for use in TN-C networks and for protecting systems in which electronic equipment may cause pulsating or smooth DC residual currents or residual currents with frequencies not equal to 50 Hz. Comprehensive protection is not provided with an RCCB type AC. For these applications we recommend our residual current operated circuit-breakers with integral overcurrent protection Type A or our AC-DC sensitive RCBO Type B.