residual current operated circuit-breakers with integral overcurrent protection DRCBO 4 C06/0,30/3N-A

09945131, Residual current operated circuit-breaker with integral overcurrent protection, three-pole+N, 6 A, 0,3 A, C-characteristic, Type A

residual current operated circuit-breakers with integral overcurrent protection DRCBO 4 C06/0,30/3N-A

09945131, Residual current operated circuit-breaker with integral overcurrent protection, three-pole+N, 6 A, 0,3 A, C-characteristic, Type A

Details

Residual current operated circuit-breaker with integral overcurrent protection, three-pole+N, 6 A, 0,3 A, C-characteristic, Type A

RCBOs combine residual current and miniature circuit-breakers in a single device (RCBO). They protect people against residual currents and systems against short-circuit and overload. The DRCBO 4 have a rated switching capacity of 6 kA. They provide a labelling area in addition to the tripping indicator. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches with tripping characteristic C are optimised for electric circuits with high inrush or peak currents. Standard switches are designed for electric circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz.

pulsating current-sensitive and AC current-sensitive, mains-voltage-independent tripping, compact design for all rated currents, switch position indicator, separate indication of tripping cause, strain-relief clamps with a wide terminal cross-section range on both connection sides, neutral conductor right, labelling area

quick fastening to mounting rail, any installation position, supply as desired

Protection of circuits in residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the RCCB/MCBs can be set to switch off in the event of a second earth fault, Not permitted for use in systems with TN-C networks; not permitted for protecting circuits in which the power electronics equipment may cause smooth DC residual currents or residual currents with frequencies not equal to 50/60 Hz.

Residual current operated circuit-breaker with integral overcurrent protection, three-pole+N, 6 A, 0,3 A, C-characteristic, Type A

RCBOs combine residual current and miniature circuit-breakers in a single device (RCBO). They protect people against residual currents and systems against short-circuit and overload. The DRCBO 4 have a rated switching capacity of 6 kA. They provide a labelling area in addition to the tripping indicator. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Switches with tripping characteristic C are optimised for electric circuits with high inrush or peak currents. Standard switches are designed for electric circuits with a rated voltage of 230 V or 400 V and a rated frequency of 50 Hz.

pulsating current-sensitive and AC current-sensitive, mains-voltage-independent tripping, compact design for all rated currents, switch position indicator, separate indication of tripping cause, strain-relief clamps with a wide terminal cross-section range on both connection sides, neutral conductor right, labelling area

quick fastening to mounting rail, any installation position, supply as desired

Protection of circuits in residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the RCCB/MCBs can be set to switch off in the event of a second earth fault, Not permitted for use in systems with TN-C networks; not permitted for protecting circuits in which the power electronics equipment may cause smooth DC residual currents or residual currents with frequencies not equal to 50/60 Hz.