residual current operated circuit-breakers with integral overcurrent protection DRCBO 3 C10/0,01/1N-A
- sensitive to pulsating and alternating currents, mains-voltage-independent
- VDE certified


residual current operated circuit-breakers with integral overcurrent protection DRCBO 3 C10/0,01/1N-A
- sensitive to pulsating and alternating currents, mains-voltage-independent
- VDE certified
Details
Residual current operated circuit-breaker with integral overcurrent protection, one-pole+N, 10 A, 0,01 A, 10 kA, C-characteristic, Type A
RCBOs combine residual current protection and overcurrent protection in a single device. This makes them ideal for use in distribution boards where space is limited. The rated breaking capacity of the 1-pole+N DRCBO 3 series is 10 kA. Type A circuit-breakers detect pulsating direct current and alternating current. With tripping characteristic C, these circuit-breakers ensure reliable protection for your circuits with loads that generate higher inrush peaks. Standard circuit-breakers are designed for circuits with 230 V or 400 V at 50 Hz.
tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents and pulsating DC residual currents (type A), compact design for all rated currents, high short-circuit resistance, green/red switching position indicator, residual current tripping indicator, Strain-relief clamps with protection against wires being lodged behind them and wide terminal cross-section range for rail and line wiring on both connection sides, Use of conventional wiring rails possible, Neutral conductor right, tri-stable snap-in slider for easy mounting and removal, high electromagnetic compatibility (immunity to interference for industrial applications)
quick fastening to mounting rail, any installation position, supply as desired
Protection of circuits in residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the RCCB/MCBs can be set to switch off in the event of a second earth fault, Not permitted for use in systems with TN-C networks; not permitted for protecting circuits in which the power electronics equipment may cause smooth DC residual currents or residual currents with frequencies not equal to 50/60 Hz.
- Data sheet DRCBO 3 C10/0,01/1N-A
- Operating instructions
- Technical information derating graph
- Technical information dissipation power
- Prospectus DRCBO 3
- Prospectus Circuit-breaker overview
- Text for invitation to tender RTF
- Text for invitation to tender GAEB XML
- Text for invitation to tender GAEB 2000
- Text for invitation to tender GAEB 90
- Dimensional drawing Group view
- STEP file
- Wiring diagram
Residual current operated circuit-breaker with integral overcurrent protection, one-pole+N, 10 A, 0,01 A, 10 kA, C-characteristic, Type A
RCBOs combine residual current protection and overcurrent protection in a single device. This makes them ideal for use in distribution boards where space is limited. The rated breaking capacity of the 1-pole+N DRCBO 3 series is 10 kA. Type A circuit-breakers detect pulsating direct current and alternating current. With tripping characteristic C, these circuit-breakers ensure reliable protection for your circuits with loads that generate higher inrush peaks. Standard circuit-breakers are designed for circuits with 230 V or 400 V at 50 Hz.
tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents and pulsating DC residual currents (type A), compact design for all rated currents, high short-circuit resistance, green/red switching position indicator, residual current tripping indicator, Strain-relief clamps with protection against wires being lodged behind them and wide terminal cross-section range for rail and line wiring on both connection sides, Use of conventional wiring rails possible, Neutral conductor right, tri-stable snap-in slider for easy mounting and removal, high electromagnetic compatibility (immunity to interference for industrial applications)
quick fastening to mounting rail, any installation position, supply as desired
Protection of circuits in residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the RCCB/MCBs can be set to switch off in the event of a second earth fault, Not permitted for use in systems with TN-C networks; not permitted for protecting circuits in which the power electronics equipment may cause smooth DC residual currents or residual currents with frequencies not equal to 50/60 Hz.
- Data sheet DRCBO 3 C10/0,01/1N-A
- Operating instructions
- Technical information derating graph
- Technical information dissipation power
- Prospectus DRCBO 3
- Prospectus Circuit-breaker overview
- Text for invitation to tender RTF
- Text for invitation to tender GAEB XML
- Text for invitation to tender GAEB 2000
- Text for invitation to tender GAEB 90
- Dimensional drawing Group view
- STEP file
- Wiring diagram