residual current circuit-breaker DFS 2 040-2/0,03-F Hz60 V290

09134030, Residual current circuit-breakers, two-pole, 40 A, 0,03 A, Type F, 60 Hz/290 V, N left or right
  • sensitive to mixed frequencies, mains-voltage-independent
  • Rated frequency 60 Hz / Rated voltage (AC) 290 V
  • higher system availability: short-time delayed
  • minimal power dissipation at each pole
  • large connection terminals up to 50 mm²

residual current circuit-breaker DFS 2 040-2/0,03-F Hz60 V290

09134030, Residual current circuit-breakers, two-pole, 40 A, 0,03 A, Type F, 60 Hz/290 V, N left or right
  • sensitive to mixed frequencies, mains-voltage-independent
  • Rated frequency 60 Hz / Rated voltage (AC) 290 V
  • higher system availability: short-time delayed
  • minimal power dissipation at each pole
  • large connection terminals up to 50 mm²

Details

Residual current circuit-breakers, two-pole, 40 A, 0,03 A, Type F, 60 Hz/290 V, N left or right

Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 2 are two-terminal residual current circuit-breakers for single-phase networks. In the standard design, the compact devices are just two module widths wide. They are available with many different residual current types and variants for rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. The trip position of the multi-function toggle switch simplifies fault-finding. The free label software helps in the labelling process. Type F switches are mixed frequency sensitive. They protect against pulsating and AC residual currents as well as residual currents with mixed frequencies that differ from 50 Hz independent of the mains voltage. Residual current circuit-breakers in the Hz design are intended for rated mains frequencies other than 50 Hz. The frequency range for tripping current detection remains unaffected by this. Devices in design V are made for special voltages.

sensitive to AC residual currents and pulsating DC residual currents at the mains frequency (type A) as well as AC residual currents with multiple frequency components not equal to 50 Hz, high immunity against surge currents and mains-voltage-operated secondary current impulses , compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor cross-section and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "off" and "tripped", Neutral conductor position left or right

quick fastening to mounting rail, any installation position, supply from any direction

Residual current circuit-breakers, two-pole, 40 A, 0,03 A, Type F, 60 Hz/290 V, N left or right

Residual current circuit-breakers (RCCB) switch the power supply off if dangerous high residual currents occur. DFS 2 are two-terminal residual current circuit-breakers for single-phase networks. In the standard design, the compact devices are just two module widths wide. They are available with many different residual current types and variants for rated currents up to 125 A. The large two-tier terminals can also accommodate large conductor cross-sections. The trip position of the multi-function toggle switch simplifies fault-finding. The free label software helps in the labelling process. Type F switches are mixed frequency sensitive. They protect against pulsating and AC residual currents as well as residual currents with mixed frequencies that differ from 50 Hz independent of the mains voltage. Residual current circuit-breakers in the Hz design are intended for rated mains frequencies other than 50 Hz. The frequency range for tripping current detection remains unaffected by this. Devices in design V are made for special voltages.

sensitive to AC residual currents and pulsating DC residual currents at the mains frequency (type A) as well as AC residual currents with multiple frequency components not equal to 50 Hz, high immunity against surge currents and mains-voltage-operated secondary current impulses , compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor cross-section and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "off" and "tripped", Neutral conductor position left or right

quick fastening to mounting rail, any installation position, supply from any direction