residual current circuit-breaker DFS 4 016-4/0,10-AC R

09115912, Residual current circuit-breakers, four-pole, 16 A, 0,1 A, Type AC, N right
Achtung
The use of these devices is not permitted in all countries. Pay attention to the according national installation regulations.
  • sensitive to alternating currents, mains-voltage-independent
  • minimal power dissipation at each pole
  • large connection terminals up to 50 mm²

residual current circuit-breaker DFS 4 016-4/0,10-AC R

09115912, Residual current circuit-breakers, four-pole, 16 A, 0,1 A, Type AC, N right
Achtung
The use of these devices is not permitted in all countries. Pay attention to the according national installation regulations.
  • sensitive to alternating currents, mains-voltage-independent
  • minimal power dissipation at each pole
  • large connection terminals up to 50 mm²

Details

Residual current circuit-breakers, four-pole, 16 A, 0,1 A, Type AC, N right

Type AC residual current circuit-breakers only detect alternating fault currents. In the UK, they are only approved for use with fixed equipment, where it is known that the load current contains no DC components. Standard RCCBs are designed for circuits with 230/400 V at 50 Hz.

tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents (type AC) , compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor cross-section and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "off" and "tripped", Neutral conductor position right

quick fastening to mounting rail, any installation position, supply from any direction

Power supplies to residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the residual current circuit-breakers of this series can be set to switch off in the event of a second fault, Not permitted for use in TN-C networks; not permitted for protecting systems in which electronic equipment may cause pulsating or smooth DC residual currents or residual currents with frequencies not equal to 50 Hz. Comprehensive protection is not provided with an RCCB type AC. For these applications we recommend our residual current circuit-breaker type A or our AC/DC sensitive residual current circuit-breaker type B/B+.

Residual current circuit-breakers, four-pole, 16 A, 0,1 A, Type AC, N right

Type AC residual current circuit-breakers only detect alternating fault currents. In the UK, they are only approved for use with fixed equipment, where it is known that the load current contains no DC components. Standard RCCBs are designed for circuits with 230/400 V at 50 Hz.

tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents (type AC) , compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor cross-section and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "off" and "tripped", Neutral conductor position right

quick fastening to mounting rail, any installation position, supply from any direction

Power supplies to residential and purpose-built buildings as well as industrial facilities with TN-S, TT and TN-C-S networks. In IT networks, the residual current circuit-breakers of this series can be set to switch off in the event of a second fault, Not permitted for use in TN-C networks; not permitted for protecting systems in which electronic equipment may cause pulsating or smooth DC residual currents or residual currents with frequencies not equal to 50 Hz. Comprehensive protection is not provided with an RCCB type AC. For these applications we recommend our residual current circuit-breaker type A or our AC/DC sensitive residual current circuit-breaker type B/B+.