residual current circuit-breaker DFS 4 080-4/0,03-A EV HD
- sensitive to pulsating and alternating currents, mains-voltage-independent
- for electromobility
- "HD" design: resistant against corrosive gases and moisture
- minimal power dissipation at each pole
- large connection terminals up to 50 mm²
- VDE certified


residual current circuit-breaker DFS 4 080-4/0,03-A EV HD
- sensitive to pulsating and alternating currents, mains-voltage-independent
- for electromobility
- "HD" design: resistant against corrosive gases and moisture
- minimal power dissipation at each pole
- large connection terminals up to 50 mm²
- VDE certified
Details
Residual current circuit-breakers, four-pole, 80 A, 0,03 A, Type A, for electromobility, N left, HD
Type A residual current circuit-breakers detect pulsating direct current and alternating current. Our EV RCCB was specifically developed for use in charging stations for electric vehicles. The EV RCCBs detect smooth DC residual currents and safely trip at 6 mA DC. This protects upstream type A or F RCCBs and ensures maximum safety at your charging station. The HD design makes our RCCBs particularly resistant to harmful environmental influences and therefore suitable for harsh environments.
additional mains-voltage-dependent function for detecting smooth DC residual currents, Tripping threshold of 6 mA for smooth DC residual currents , tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents and pulsating DC residual currents (type A), compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor cross-section and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "off" and "tripped", Neutral conductor position left
quick fastening to mounting rail, any installation position, supply from any direction
These RCCBs are only designed for use in charging stations for electric vehicles, Not permitted for protecting systems in which electronic equipment may cause residual currents with frequencies not equal to 50 Hz. AC/DC sensitive residual current circuit-breakers of type B or B+ must be used in this case.
- Data sheet DFS4 080-4/0,03-A EV HD
- Operating instructions
- Technical information Derating graph for DFS 2/4
- Technical information dissipation power DFS 2/4
- Prospectus EV design
- Prospectus Circuit-breaker overview
- Prospectus DFS HD "heavy duty"
- Prospectus Energy transition
- Text for invitation to tender RTF
- Text for invitation to tender GAEB XML
- Text for invitation to tender GAEB 2000
- Text for invitation to tender GAEB 90
- Dimensional drawing Group view
- STEP file
- Wiring diagram
- Product video DFS for electromobility
- Labelling software DFS / DLS
- Download link Cadenas library
Residual current circuit-breakers, four-pole, 80 A, 0,03 A, Type A, for electromobility, N left, HD
Type A residual current circuit-breakers detect pulsating direct current and alternating current. Our EV RCCB was specifically developed for use in charging stations for electric vehicles. The EV RCCBs detect smooth DC residual currents and safely trip at 6 mA DC. This protects upstream type A or F RCCBs and ensures maximum safety at your charging station. The HD design makes our RCCBs particularly resistant to harmful environmental influences and therefore suitable for harsh environments.
additional mains-voltage-dependent function for detecting smooth DC residual currents, Tripping threshold of 6 mA for smooth DC residual currents , tripping not dependent on mains and auxiliary voltage, sensitive to AC residual currents and pulsating DC residual currents (type A), compact design for all rated currents, high short-circuit resistance, double-sided two-tier terminals for large conductor cross-section and busbar, switch position indicator, viewing window for labels, multifunction switch toggle with three positions: "on", "off" and "tripped", Neutral conductor position left
quick fastening to mounting rail, any installation position, supply from any direction
These RCCBs are only designed for use in charging stations for electric vehicles, Not permitted for protecting systems in which electronic equipment may cause residual currents with frequencies not equal to 50 Hz. AC/DC sensitive residual current circuit-breakers of type B or B+ must be used in this case.
- Data sheet DFS4 080-4/0,03-A EV HD
- Operating instructions
- Technical information Derating graph for DFS 2/4
- Technical information dissipation power DFS 2/4
- Prospectus EV design
- Prospectus Circuit-breaker overview
- Prospectus DFS HD "heavy duty"
- Prospectus Energy transition
- Text for invitation to tender RTF
- Text for invitation to tender GAEB XML
- Text for invitation to tender GAEB 2000
- Text for invitation to tender GAEB 90
- Dimensional drawing Group view
- STEP file
- Wiring diagram
- Product video DFS for electromobility
- Labelling software DFS / DLS
- Download link Cadenas library





