Miniature circuit-breakers ELS 3 C04/1+N

09915030, Circuit-breakers, one-poleyes, Characteristic C, 4 A, 6 kA
* Picture similar to the actual unit

Miniature circuit-breakers ELS 3 C04/1+N

09915030, Circuit-breakers, one-poleyes, Characteristic C, 4 A, 6 kA
* Picture similar to the actual unit

Details

Circuit-breakers, one-poleyes, Characteristic C, 4 A, 6 kA

Miniature circuit-breakers (MCB), commonly referred to as a fuses, switch an electric circuit off in the event of overcurrent or short-circuit and protect the electric lines against damage. Miniature circuit-breakers from series ELS have a compact design. A guide phase and neutral conductor (1+N) are monitored at a width of only 1 TE. Furthermore, they feature a contact position indicator and protection against wires behind lodged behind terminals. They can be used for rated short-circuit currents up to 6 kA. Switches with tripping characteristic C are optimised for power circuits with high inrush or peak currents.

high-quality miniature circuit-breakers 1+N in 1 module width unit for space-saving installation, switching position indicator red/green, Protection against wires being lodged behind terminals, extensive range of accessories which can be retro-fitted, rated currents up to 40 A, rated switching capacity 6 kA as per EN 60898

quick fastening to mounting rail, any installation position

suitable for use in power supplies for industrial facilities and purpose-built buildings or buildings for commercial use

Circuit-breakers, one-poleyes, Characteristic C, 4 A, 6 kA

Miniature circuit-breakers (MCB), commonly referred to as a fuses, switch an electric circuit off in the event of overcurrent or short-circuit and protect the electric lines against damage. Miniature circuit-breakers from series ELS have a compact design. A guide phase and neutral conductor (1+N) are monitored at a width of only 1 TE. Furthermore, they feature a contact position indicator and protection against wires behind lodged behind terminals. They can be used for rated short-circuit currents up to 6 kA. Switches with tripping characteristic C are optimised for power circuits with high inrush or peak currents.

high-quality miniature circuit-breakers 1+N in 1 module width unit for space-saving installation, switching position indicator red/green, Protection against wires being lodged behind terminals, extensive range of accessories which can be retro-fitted, rated currents up to 40 A, rated switching capacity 6 kA as per EN 60898

quick fastening to mounting rail, any installation position

suitable for use in power supplies for industrial facilities and purpose-built buildings or buildings for commercial use